Part 1 specification – IAI America REXT User Manual

Page 95

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

73

Part 1 Specification

I/O Signal List

Signal type

Bit

Signal name

Description

Details

Position data

specification

32-bit

data

-

Set as a hexadecimal number using a 32-bit signed integer

(unit: 0.01 mm)

Example) To set +25.4 mm, specify “0009ECH”

(decimal number: 2540).

z

The maximum settable value is +9999.99 mm = 999999

(decimal number) = 0F423FH (hexadecimal number).

z

If the applicable data is a negative value, specify it as a

complement of 2.

z

Set the position data within the soft stroke range.

3.8.3 (5)

Positioning band 32-bit

data

-

Set as a hexadecimal number using a 32-bit integer

(unit: 0.01 mm).

Example) To set +25.4 mm, specify “0009ECH”

(decimal number: 2540).

z

Set the position data within the soft stroke range.

z

Set the direction of push operation using the DIR.

z

Take note that if positioning band specification data is not set,

the setting of parameter No. 10, “Default positioning band” will

not be applied.

3.8.3 (5)

Speed

16-bit

data

-

Set as a hexadecimal number using a 16-bit integer

(unit: 1.0 mm/sec or 0.1 mm/sec).

Example) To set 200 mm/sec, specify “00C8H”

(decimal number: 200).

z

If speed is not set, or the set speed is “0,” the actuator will

remain stopped and no alarm will generate.

If the speed setting is changed to “0” while the actuator is

moving, the actuator will decelerate to a stop.

z

Change the unit on the special parameter setting screen of

the ROBONET gateway parameter setting tool. (The unit

change function is supported by applications of version

1.0.4.0 and later.) (The factory setting is 1.0 mm/sec.)

3.8.3 (5)

P

LC

o

ut

pu

t

Acceleration/

deceleration

16-bit

data

-

Set as a hexadecimal number using a 16-bit integer (unit: 0.01 G).

Example) To set 0.2 G, specify “0014H” (decimal number: 20).

The maximum value is 2 G, corresponding to “00C8H” (decimal

number: 200).

z

Take note that if acceleration/deceleration is not set, the

setting of parameter No. 9, “Default

acceleration/deceleration” will not be applied.

z

Separate values cannot be set for acceleration and

deceleration. The acceleration and deceleration are always

the same.

3.8.3 (5)