Caution

[1] When the start signal (CSTR) is turned “1” (ON), the position complete signal (PEND) will turn “0” (OFF) and the

moving signal (MOVE) will turn “1” (ON).

Turn the start signal (CSTR) “0” (OFF) after confirming that the position complete signal (PEND) has turned “0” (OFF)

when CSTR is turned “1” (ON).

[2] By setting a large positioning band for position 1, speed change can be implemented smoothly without causing the

actuator to stop.

Caution

If a pause command is issued during home return, the move command will be retained if the actuator has not yet contacted

a mechanical end. If the actuator has already reversed its direction after contacting a mechanical end, however, home

return will be repeated from the beginning.