Part 1 Specification

Chapter 3 Gateway R unit

117

Part 1 Specification

3.8.5 Command Transmission

A command transmission chart is shown below.

The Gateway R unit analyzes each request command and returns a response every time the replacement of control/status

data of all axes, which is performed constantly, is completed.

The PLC and Gateway R unit perform the following actions:

[1] Upon detecting a response command with zero set in it, the PLC application sets the necessary request command and

data.

[2] Upon detecting the change of the request command to a value other than zero, the gateway sends the request data to the

applicable axis.

[3] Upon receiving a response from the applicable axis, the gateway outputs the response result.

[4] Upon confirming the response result, the PLC application clears the request command.

[5] Upon detecting the clearing of the request command, the gateway clears the response command and waits for the next

command.

[1] to [5] are repeated if commands are used consecutively.

䠄 3/& 䊻*:䠅

PLC request

Gateway response

Request command,

data

Controller command

transmission via the

gateway

Response command,

response data

Response = 0000H

Request = 0000H

-141-