Part 3 maintenance, 1 common alarms – IAI America REXT User Manual

Page 384

Advertising
background image



Part 3 Maintenance

Chapter 1 T

roubleshooting

352

Part 3 Maintenance

1.2.1 Common Alarms

The table below lists the alarms and their descriptions.

LED name

Displayed

color

Condition

Action

Green

Normal

-

RUN/ALM

Orange

An alarm is present (applicable to all

alarms).

Check the ERROR-T/C and STATUS-0/1

LEDs.

Red

An emergency stop is actuated.

Check the emergency-stop pushbutton and

emergency-stop circuit.

EMG

Unlit

An emergency stop is not actuated.

-

Unlit

Normal

-

ERROR-T

Orange

ROBONET communication error

[1] The axis configuration parameters do

not match the actual axis configuration

(address).

[1] Review the parameter settings and

address setting.

[2] Internal bus communication with the

controller experienced an error.

[2] Check the status of the SV/ALM and

TX/RX LEDs on the controller unit to

identify the axis that generated the

error.

Turn off the power and then turn it

back on.

Check the ROBONET communication

connection board for proper insertion.

[3] Not all controllers are ready.

[3] The ROBONET link is operating

normally, but the CRDY signal of a

specific axis is turned OFF. Monitor

each axis to identify and replace the

problem axis.

Unlit

Normal

-

ERROR-C

Orange

Fieldbus communication error

Check the details using the STATUS0 and

1 LEDs.

-384-