Position Data Load Command (PWRT)

z

Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

06 H

1

Starting address

(upper)

F6 H

Starting address

(lower)

0B H

2

Address of the control signal register of axis (0)

New data (data written) (upper)

06 H

New data (data written) (lower)

10 H

2

The MODE, PWRT and SON signals are “1.”

Error check

(CRC)

16 bits

2

(CD32) Based on calculation result

Trailer

None

-

Total bytes

8

z

Response

If the data has been changed (written) successfully, the response is the same as the query.

[Function]

When the PWRT signal changes from “0” to “1” while in the teaching mode (MODE = “1”) and this condition is

maintained for 20 msec or more after it is recognized by the controller, the current position data will be written to the

target position corresponding to the position number in the command position number register effective at the time of

detection.

If the position table is empty, the default parameters will be written together in the data fields other than the target

position (positioning band, speed, acceleration/deceleration).

z

Actual Example (Axis 0)

Load the teaching position into No. 8 of the axis (0) position table.

Inching operation in the teaching mode (MODE = “1”) 3F06F60B0530CC1A

(Repeated inching operations)

Specification of command position number (Ex: 8)

3F06F60B0430CD8A

3F06F60A00089F58

Position data load command

3F06F60B0610CD32

-176-