Part 1 Specification

Chapter 3 Gateway R unit

87

Part 1 Specification

Zone signal ON area

Set values

Zone setting+: 70q

Zone setting-: 315q

Set values

Zone setting+: 315q

Zone setting-: 70q

Set values

Zone setting+: 70 mm

Zone setting-: 30 mm

Set values

Zone setting+: 30 mm

Zone setting-: 70 mm

Examples are shown below.

[Rotary actuator in the index mode]

[Linear axis]

Current position

Zone signal output

Zone signal output

Caution

The specifics of the zone function vary depending on the application version.

y

In applications of version 0015 and older, zone signals will not be output if the parameters are set as follows:

Zone setting+ d Zone setting-

y

In applications of version 0016 and later, zone signals will not be output if the parameters are set as follows:

Zone setting+ = Zone setting-

-109-