Part 1 specification, Caution – IAI America REXT User Manual

Page 225

Advertising
background image

0

Part 1 Specification

Chapter 4 Controller Unit

201

Part 1 Specification

*2

No. Type Symbol

RPCON RACON

Name

Unit

Factory default

43

b

HMC

{

{

Home check sensor input polarity

-

(As specified at the time of order)

46

b

OVRD

{

{

Speed override

%

100

47

b

IOV2

{

{

PIO jogging speed 2

mm/sec

100

48

b

IOID

{

{

PIO inching distance

mm

0.1

49

b

IOD2

{

{

PIO inching distance 2

mm

0.1

52

b

HSTP1

X

{

Default acceleration/deceleration mode

-

0 [Trapezoid]

53

b

HSTP2

{

X

Default stop mode

-

0 [Complete stop]

54

d

CLPF

X

{

Current control band number

-

Set individually in accordance with

the actuator characteristics.

55

b

PLPF

X

{

Position-command primary filter time constant

msec

0

56

b

SCRV

X

{

S-motion ratio setting

%

0

71

b

PLFG

X

{

Position feed-forward gain

-

0

77

b

LEAD

{

{

Ball screw lead

mm

Set individually in accordance with

the actuator characteristics.

78

b

ATYP

{

{

Axis operation type

-

Set individually in accordance with

the actuator characteristics.

79

b

ATYP

{

{

Rotational axis mode selection

-

Set individually in accordance with

the actuator characteristics.

80

b

ATYP

{

{

Rotational axis shortcut selection

-

Set individually in accordance with

the actuator characteristics.

83

b

ETYP

{

{

Use absolute unit [0: Do not use / 1: Use]

-

Set individually in accordance with

the actuator characteristics.

91

B

PSFC

{

{

Current-limiting value at standstill after missing work

part in push operation

[0: Current-limiting value during movement /

1: Push-current limiting value]

-

0: Current-limiting value during

movement

*1

*1 {: Available X: Not available

*2 The parameter numbers are displayed in the PC software, but not on the teaching pendant. Missing numbers are not used

and are thereby omitted. Types are indicated solely for the purpose of convenience and are not displayed.

Caution

If you have changed any parameter, be sure to restart the controller via a software reset or reconnect the controller power.

-225-

Advertising
This manual is related to the following products: