(15) Jogging Speed/Inching Distance Switching (JVEL) PLC Output Signal

This signal switches between the parameter for specifying the jogging speed when jogging operation is selected and the

parameter for specifying the inching distance when inching operation is selected.

The relationships are summarized in the table below.

JVEL signal

Jogging operation: JISL = “0” (OFF)

Inching operation: JISL = “1” (ON)

“0” (OFF) Parameter No. 26 (Jogging speed)

Parameter No. 26 (Jogging speed)

Parameter No. 48 (Inching distance)

“1” (ON)

Parameter No. 47 (Jogging speed 2)

Parameter No. 47 (Jogging speed 2)

Parameter No. 49 (Inching distance 2)

(16) Jogging/Inching Switching (JISL) PLC Output Signal

This signal is used to switch jogging operation and inching operation.

JISL = “0” (OFF): Jogging operation

JISL = “1” (ON): Inching operation

If the JISL signal switches to “1” (ON) during jogging operation, the actuator will decelerate to a stop and the inching

function will become effective. If the JISL signal switches to “0” (OFF) during inching operation, the actuator will

complete the inching operation and then the jogging function will become effective.

Jogging and inching operation commands are based on a combination of JISL, JVEL and JOG+/JOG- signals. The

relationships of these signals are summarized in the table below.

Jogging operation

Inching operation

JISL

“0” (OFF)

“1” (ON)

Speed

Parameter No. 26 (Jogging speed)

Parameter No. 26 (Jogging speed)

Travel distance

-

Parameter No. 48 (Inching distance)

JVEL=

“0” (OFF) Acceleration/

deceleration

Rated value (The specific value varies

depending on the actuator.)

Rated value (The specific value varies

depending on the actuator.)

Speed

Parameter No. 47 (Jogging speed 2)

Parameter No. 47 (Jogging speed 2)

Travel distance

-

Parameter No. 49 (Inching distance 2)

JVEL=

“1” (ON)

Acceleration/

deceleration

Rated value (The specific value varies

depending on the actuator.)

Rated value (The specific value varies

depending on the actuator.)

Operation

When the JOG+/JOG- is “1”

When the JOG+/JOG- changes from

“0” from “1”