Part 2 startup chapter, 6 external sio link of robonet – IAI America REXT User Manual

Page 282

Advertising
background image

0

Part 2 Startup Chapter

Chapter 2 Mounting and Installation

258

Part 2 Startup Chapter

4-way junction

GatewayR unit

Extension unit

Unit link cable

Extension unit [2]

Extension unit [3]

Terminal resistor

Junction

interconnection cable

Controller link cable

Network connection

cable

Terminal Power-supply &

I/O cable

Controller

connection cable

SCON or PCON-CF

24-VDC control power, motor power,

brake signal, ground, shield

2.2.6 External SIO Link of ROBONET

An example of implementing an external SIO

link using REXT extension units is shown to

the right.

In this example, the first stage and second

stage comprise a multi-stage layout, while the

last extension unit [3] in the second stage is

linked to a SCON or PCON-CF via SIO link.

(1) The units are installed on DIN rails.

(2) The multi-stage layout of the first stage

and second stage is the same as in 2.2.5.

Refer to 2.2.5.

(3) Connect each extension unit to an

adjacent unit using the power supply

connection plate and communication

connection circuit board supplied with

the extension unit.

(4) Place the extension unit for SIO link at

the end of the lowermost stream (bottom

stage) (extension unit [3]) and connect

the controller connection cable

(CB-REXT-CTL-) to the downstream unit

connector on the extension unit. Connect

the grounding wire with a M3 round

terminal to the FG terminal block.

(5) Connect the e-CON connector end of the

controller connection cable to a 4-way

junction.

(6) Connect the SCON or PCON-CF and

4-way junction using an optional

controller link cable (CB-RCB-CTL002).

The controller link cable

CB-RCB-CTL002 comes with the

following accessories. Use them to make

the connection as shown to the right:

x

4-way junction

(5-1473574-4 by AMP)

x 1

x

e-CON connector

(4-1473562-4)

x 1

x

Terminal resistor 220 :

(with e-CON connector)

x 1

The customer must fabricate a junction

interconnection cable using the above

e-CON connector supplied with the

controller link cable.

Connect the ERC2-SE and 4-way

junction using the power-supply & I/O

cable (CB-ERC2-PWBIO) and network

connection cable (CB-ERC2-CTL001)

supplied with the ERC2-SE.

-282-