Part 1 Specification

Chapter 3 Gateway R unit

43

Part 1 Specification

„

Example of Overall CC-Link Address Configuration (positioner 2 mode and solenoid valve modes 1 and 2)

An example of connecting 16 axes in the positioner 2 mode or solenoid valve mode 1 or 2 is shown below.

PLC output Ÿ ROBONET

ROBONETŸ PLC input

Output

register

Upper byte

Lower byte

Input

register

Upper byte

Lower byte

RY0F to 00

Gateway control signal 0

RX0F to 00

Gateway status signal 0

RY1F to 10

Gateway control signal 1

RX1F to 10

Gateway status signal 1

RY2F to 20

Request command

RX2F to 20

Response command

RY3F to 30

Data 0

RX3F to 30

Data 0

RY4F to 40

Data 1

RX4F to 40

Data 1

RY5F to 50

Data 2

RX5F to 50

Data 2

RY6F to 60

Data 3

RX6F to 60

Data 3

RY7F to 70

(Cannot be used)

RX7F to 70

(Cannot be used)

8-word

fixed area

*1

Output register

Input register

PLC master expanded

cyclic setting

R

Ww 00H

(Axis 0) Command position number

R

Wr 00H

(Axis 0) Completed position number

R

Ww 01H

(Axis 0) Control signal

R

Wr 01H

(Axis 0) Status signal

R

Ww 02H

(Axis 1) Command position number

R

Wr 02H

(Axis 1) Completed position number

R

Ww 03H

(Axis 1) Control signal

R

Wr 03H

(Axis 1) Status signal

2 words

R

Ww 04H

(Axis 2) Command position number

R

Wr 04H

(Axis 2) Completed position number

R

Ww 05H

(Axis 2) Control signal

R

Wr 05H

(Axis 2) Status signal

R

Ww 06H

(Axis 3) Command position number

R

Wr 06H

(Axis 3) Completed position number

R

Ww 07H

(Axis 3) Control signal

R

Wr 07H

(Axis 3) Status signal

R

Ww 08H

(Axis 4) Command position number

R

Wr 08H

(Axis 4) Completed position number

R

Ww 09H

(Axis 4) Control signal

R

Wr 09H

(Axis 4) Status signal

R

Ww 0AH

(Axis 5) Command position number

R

Wr 0AH

(Axis 5) Completed position number

R

Ww 0BH

(Axis 5) Control signal

R

Wr 0BH

(Axis 5) Status signal

R

Ww 0CH

(Axis 6) Command position number

R

Wr 0CH

(Axis 6) Completed position number

R

Ww 0DH

(Axis 6) Control signal

R

Wr 0DH

(Axis 6) Status signal

R

Ww 0EH

(Axis 7) Command position number

R

Wr 0EH

(Axis 7) Completed position number

16 words

x1 setting,

4 stations

*2

R

Ww 0FH

(Axis 7) Control signal

R

Wr 0FH

(Axis 7) Status signal

RWw 10H

(Axis 8) Command position number

R

Wr 10H

(Axis 8) Completed position number

RWw 11H

(Axis 8) Control signal

R

Wr 11H

(Axis 8) Status signal

RWw 12H

(Axis 9) Command position number

R

Wr 12H

(Axis 9) Completed position number

RWw 13H

(Axis 9) Control signal

R

Wr 13H

(Axis 9) Status signal

RWw 14H

(Axis 10) Command position number

R

Wr 14H

(Axis 10) Completed position number

RWw 15H

(Axis 10) Control signal

R

Wr 15H

(Axis 10) Status signal

RWw 16H

(Axis 11) Command position number

R

Wr 16H

(Axis 11) Completed position number

RWw 17H

(Axis 11) Control signal

R

Wr 17H

(Axis 11) Status signal

RWw 18H

(Axis 12) Command position number

R

Wr 18H

(Axis 12) Completed position number

RWw 19H

(Axis 12) Control signal

R

Wr 19H

(Axis 12) Status signal

RWw 1AH

(Axis 13) Command position number

R

Wr 1AH

(Axis 13) Completed position number

RWw 1BH

(Axis 13) Control signal

R

Wr 1BH

(Axis 13) Status signal

RWw 1CH

(Axis 14) Command position number

R

Wr 1CH

(Axis 14) Completed position number

RWw 1DH

(Axis 14) Control signal

R

Wr 1DH

(Axis 14) Status signal

RWw 1EH

(Axis 15) Command position number

R

Wr 1EH

(Axis 15) Completed position number

32 words

x4 setting,

2 stations

RWw 1FH

(Axis 15) Control signal

R

Wr 1FH

(Axis 15) Status signal

*1 The extended cyclic setting is based on the occupied area information displayed using the gateway parameter setting tool.

*2 CC-Link Version 1.10 is also supplied as long as the expanded cyclic setting of x1 (four stations occupied) can be used.

-63-