Part 2 startup chapter chapter 4 absolute reset, 1 overview of simple absolute system – IAI America REXT User Manual

Page 298

Advertising
background image



Part 2 Startup Chapter

Chapter 4

Absolute Reset

272

Part 2 Startup Chapter

Chapter 4 Absolute Reset

4.1 Overview of Simple Absolute System

To combine the RPCON or RACON controller unit with the simple absolute R unit for use as an absolute axis, an absolute

reset must be performed. Once an absolute reset is performed, home return will no longer be required every time the power to

the controller unit is turned off.

An internal block diagram of the simple absolute R unit is shown below.

The startup procedure is as follows:

[1]

Set the configuration switches (piano switches)

[2]

Connect the backup battery

[3]

Perform an absolute reset

Controller unit

Simple absolute R unit

Encoder input

connector

Incremental

pulses

Absolute data

(Serial

communication)

CPU control circuit

U/D counter

(Creation of

absolute data)

Encoder

receive

circuit

Backup battery

Encoder signal

(incremental)

Actuator

-298-