0

Part 1 Specification

Chapter 3 Gateway R unit

105

Part 1 Specification

3.8.4 Other Basic Operations

(1) Push operation

[1] Basic operation

As shown below, the actuator moves to the specified target position, and then moves at the specified push speed by

up to the specified positioning band while pushing the work part.

The moment the push force reaches a certain value during push movement, completion of push is recognized and

the position complete signal turns “1” (ON).

x

Image of push direction

As shown above, when the actuator pushes from the start point to the target position the direction in which the coordinate

increases is defined as the positive (+) direction, while the direction in which the coordinate decreases is defined as the

negative (-) direction. Exercise caution because if the push direction is set incorrectly, the actuator will not operate correctly

and push the work part at a position offset toward the start point by the distance of “positioning band x 2.”

Speed

When the load is contacted, completion of push is recognized

and the position complete signal turns ON.

Travel distance

Push speed

Target position

Positioning band (maximum distance traveled in push operation)

Actuator

H

om

e

Start

point

Ta

rg

et

p

os

iti

on

Push direction

Positioning band

(sign +)

Actuator

H

om

e

Start

point

Push direction

Positioning band

(sign -)

Speed

Start point

Target position

Position

When the sign is

set to (-)

When the sign is

set to (+)

Position

Start point

Speed

Positioning

band

Target position

Positioning

band

Positioning

band

Positioning

band

Correct operation

Correct operation

Ta

rg

et

p

os

iti

on

-129-