[3] Output control signals (Axis 0 = Positioner mode or simple direct mode)

An example of control signals of axis (0) is explained.

The configuration of the control signal register of axis (0) is shown below.

‹

Servo ON Command (SON)

z

Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

06 H

1

Starting address

(upper)

F6 H

Starting address

(lower)

0B H

2

Address of the control signal register of axis (0)

New data (data written) (upper)

00 H

New data (data written) (lower)

10 H

2

Error check

(CRC)

16 bits

2

Based on calculation result

Trailer

None

-

Total bytes

8

z

Response

If the data has been changed (written) successfully, the response is the same as the query.

z

Actual Example

„

Sent Query:

3F06F60B0010CE92

„

Received Response: 3F06F60B0010CE92

Address

-165-