Part 1 specification – IAI America REXT User Manual

Page 155

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

131

Part 1 Specification

[3] Monitor current position – Axis (0)

z

Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

03 H

1

Starting address

(upper)

F7 H

Starting address

(lower)

08 H

2

The addresses of current position data of axis

(0) are F708H and F709H for the lower word

and upper word, respectively.

Number of registers (upper)

00 H

Number of registers (lower)

02 H

2

Number of registers (1 register = 1 word): 2

Error check

(CRC)

Based on

calculation result

2

(73 63)

Trailer

None

-

Total bytes

8

z

Response

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

03 H

1

Data bytes

04 H

1

1-word register x 2 = 4 bytes

Data 1

(upper)

Arbitrary

Data 1

(lower)

Arbitrary

1 each for upper

and lower words

2

Lower word of the current position

Data 2

(upper)

Arbitrary

Data 2

(lower)

Arbitrary

Same as above Upper word of the current position

Error check

(CRC)

Based on

calculation result

2

Trailer

None

-

Total bytes

z

Actual Example

„

Sent Query:

3F03F70800027363

„

Received Response: 3F030438A5000038B3

(Explanation) x Lower word: 38A5H

x

Upper word: 0000H

The current position data is indicated in units of 0.01 mm.

In other words, 000038A5 H = 14501 (decimal) o 145.01 mm

-155-