Part 1 specification, Caution – IAI America REXT User Manual

Page 188

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

164

Part 1 Specification

(4) Use of Gateway Commands

The position table can be read/written by writing request commands and data in the command area of the gateway unit.

For details, refer to the specifications of the gateway unit.

An address map of the command area is shown below.

Register address

Register address

F602

Request command

Response command

F702

F603

Data 0

Data 0

F703

F604

Data 1

Data 1

F704

F605

Data 2

Data 2

F705

F606

Data 3

Data 3

F706

The table below lists the data that can be handled with these commands.

Data name

Register size

Data size

Unit

Data range

Target position

2 words

32-bit signed integer

0.01 mm

-999999 ~ 999999

Positioning band

2 words

32-bit integer

0.01 mm

Up to 999999

Speed (Note)

2 words

32-bit integer

0.01 mm/sec 0 ~ 999999

Individual zone boundary+

2 words

32-bit integer

0.01 mm

Within the actuator stroke

Individual zone boundary-

2 words

32-bit integer

0.01 mm

Within the actuator stroke

Acceleration

1 word

16-bit integer

0.01 G

Deceleration

1 word

16-bit integer

0.01 G

Within the maximum actuator

acceleration/deceleration

Push-current limiting value

1 word

8-bit integer

%

100% corresponds to FFH.

Load current threshold

1 word

8-bit integer

%

0 ~ 100 (00H ~ FFH)

Caution

When writing to the position table, the speed is specified in units of 0.01 mm/sec. Take note that in the direct numerical

specification mode, the speed is specified in units of 1.0 mm/sec.

-188-