Part 1 Specification

Chapter 3 Gateway R unit

40

Part 1 Specification

3.7 Address Configuration

ROBONET addresses are configured in the same manner with all four types of gateway units regardless of the type of field

network.

The addresses occupied by the network consist of a fixed 8-word area and a data area that changes according to the

operation mode and number of axes. The operation modes and occupied data areas are shown below.

The positioner 1 mode, simple direct mode and direct numerical specification mode can be combined, and a desired mode can

be selected for each axis. Also note that the positioner 2 mode, solenoid valve mode 1 and solenoid valve mode 2 cannot be

combined with the positioner 1 mode, simple direct mode or direct numerical specification mode.

(1) Configuration of Fixed Area

PLC output Ÿ ROBONET

ROBONET Ÿ PLC input

Upper byte

Lower byte

Number

of words

Upper byte

Lower byte

Number

of words

Gateway control signal 0

Gateway status signal 0

Gateway control

area

Gateway control signal 1

2

Gateway status signal 1

2

Request command

Response command

Data 0

Data 0

Data 1

Data 1

Data 2

Data 2

Data 3

Data 3

Command area

Cannot be used.

6

Cannot be used.

6

* In the direct numerical specification mode, the command area cannot be used, but this area is occupied as part of the data

area.

(2) Data Area Configuration in the Positioner Mode and Simple Direct Mode

PLC output Ÿ Axis input

Axis output Ÿ PLC input

Upper

byte

Lower byte

Number

of words

Positioner

mode

Simple

direct

mode

Upper

byte

Lower byte Number

of words

Positioner

mode

Simple

direct

mode

Position data specification (L)

Current position data (L)

Position data

specification area

Position data

specification (H)

2

X

{

Current position data

2

{

{

Position specification

area

Command position

number

1

{

{

Completed position

number

1

{

{

Control signal area

Control signal

1

{

{

Status signal

1

{

{

* In the positioner mode, the position data specification area (PLC Ÿ Axis input) is not used, but this area is occupied as part

of the data area.

Fixed area (8 words)

Data area

Positioner 1

mode

(4 words)

Simple direct

mode

(4 words)

Direct numerical

specification

mode (8 words)

Number of axes

Number of axes

Number of axes

Fixed area (8 words)

Number of axes

Data area

Positioner 2

mode

(2 words)

Number of axes

Solenoid valve

mode 1, solenoid

valve mode 2

(2 words)

-60-