Part 1 specification, 2 devicenet – IAI America REXT User Manual

Page 40

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

24

Part 1 Specification

3.4.2 DeviceNet

Item

Specification

Power supply

24 VDC r 10%

Current consumption

600 mA max. (*1)

An interface module certified under DeviceNet 2.0 is used.

Group 2 only server

Communication protocol

Network-powered isolated node

Bit strobe

Polling

Communication specification

Master-slave connection

Cyclic

Baud rate

500k/250k/125k [bps] (Set by a ROBONET gateway parameter)

Baud rate

Maximum network

length

Maximum branch

length

Total branch

length

500 kbps

100 m

39 m

250 kbps

250 m

78 m

125 kbps

500 m

6 m

156 m

Communication cable length (*1)

Note) When a thick DeviceNet cable is used.

Number of occupiable nodes

1 node

D

ev

ic

eN

et

s

pe

ci

fic

at

io

n

Communication power supply

Voltage: 24 VDC (Supplied from DeviceNet)

Current consumption: 60 mA

Transmission path configuration IAI’s dedicated multi-drop differential communication

Communication method

Half-duplex

Synchronization method

Asynchronous method

Transmission path type

2-wire method corresponding to EIA RS485

Baud rate

230.4k [bps]

Error control method

CRC with no parity bit (*2)

Communication cable

ROBONET communication connection circuit board (supplied), ROBONET

extension cable (when an extension unit is used)

S

IO

c

om

m

un

ic

at

io

n

sp

ec

ifi

ca

tio

n

Number of connectable units

16 axes max.

Ambient operating temperature 0 to 40qC

Ambient operating humidity

95% RH max. (non-condensing)

Operating ambience

Free from corrosive gases, flammable gases, oil mist or powder dust.

Storage temperature

-25 to 70qC

Storage humidity

95% RH max. (non-condensing)

Vibration resistance

XYZ directions:

10 to 57 Hz, half amplitude – 0.035 mm (continuous) / 0.075 mm (intermittent)

57 to 150 Hz – 4.9 m/s

2

(continuous) / 9.8 m/s

2

(intermittent)

E

nv

iro

nm

en

t c

on

di

tio

ns

Impact resistance

XYZ directions:

147 mm/s

2

, 11 ms, half-sine wave pulse

Protection degree

IP20

Weight

Approx. 140 g

External dimensions

34 W x 105 H x 73.3 D [mm]

*1: For T-branching communication, refer to the operation manuals of the master unit and the PLC installed in the master unit.

*2: CRC: Cyclic Redundancy Check

A data error detection method frequently used for synchronous transmission.

-40-