Part 1 Specification

Chapter 3 Gateway R unit

30

Part 1 Specification

3.5.3 MODE Switch

This switch is used to set the operation mode of the controller.

Status

Explanation

MANU

Manual operation: The ROBONET system can be operated using a teaching pendant or PC.

AUTO

Auto operation:

The ROBONET system is controlled via field network communication.

3.5.4 TP Connector

A connector used exclusively for connecting a teaching pendant or PC.

Connector: TCS7587-0121077 (by Hosiden)

3.5.5 User Setting Switches

These switches are used to set the operation mode of the Gateway R unit.

Normally SW3 and SW4 should remain OFF (they should be in the left positions). Do not change the settings of these

switches.

Explanation

SW No.

CC-Link

DeviceNet

Profibus

RS485SIO

SW4

Always OFF

SW3

Always OFF

SW2

Always OFF

Endian *2

ON: SIO through mode

OFF: Modbus gateway mode

SW1

When this switch is set to ON, the TP enable switch signal is effective.

*1 SW1 to SW4 are ON when set to the right side, and OFF when set to the left side.

*2 Remote I/O endian

ON

Little endian (LSB first)

PLC by Mitsubishi, Omron, etc.

OFF

Big endian (MSB first)

PLC by Siemens

3.5.6 ROBONET Communication Connector

This connector is used to connect a Modbus communication line, emergency stop signal, etc., to the axis controller unit.

Connection is made using the ROBONET communication connection circuit board supplied with the axis controller unit.

3.5.7 Power-supply Input Terminal Block

24-VDC power is input to this terminal block.

To supply power, connect the +24-V side and 0-V side to the power-supply input terminal block of the adjoining axis controller

unit using the power-supply connection plate supplied with the controller.

11. M3 screw

M3 screw

-48-