Part 2 Startup Chapter

Chapter 5 Network Setup

292

Part 2 Startup Chapter

[2]

Set the necessary items.

*

Fewer setting items may be available depending on the versions of the ROBONET gateway parameter setting

tool and firmware.

(i)

Enable operation ---

If the enable function is enabled, you can select the control method of the controller

to be applied when an enable operation is performed.

(Enable function is enabled = User setting switch (SW1) on the Gateway R unit is ON)

Selected item

Operation

Shutdown control (factory setting)

Decelerate the actuator to a stop, and then turn OFF

the servo and shut down the drive source.

Servo control

Decelerate the actuator to a stop, and then turn OFF

the servo.

(iii)

Status latch after servo OFF upon occurrence of ERR_T ---

You can select whether to turn OFF the servo of each controller and disable control commands upon

occurrence of ERR-T. The factory setting is to disable this function. (Firmware version 000F or later)

Caution

[While starting, the system is unstable and the likelihood of ERR-T occurring is high. Accordingly, start the system by

setting the control signal bit “RTE” to 1. (Refer to 3.7.2.)

Be sure to reset the “RTE” bit to 0 after confirming that the status signal bit “RUN” has switched to 1.

(iii)

Servo OFF upon occurrence of ERR_C ---

You can select whether to turn OFF the servo of each controller upon occurrence of ERR_C. The factory setting

is to enable this function. (Firmware version 000C or later)

: When starting the system

(i)

(ii)

(iii)

(iv)

(v)