Part 2 startup chapter – IAI America REXT User Manual

Page 363

Advertising
background image



Part 2 Startup Chapter

Chapter 5 Network Setup

331

Part 2 Startup Chapter

[b] When the parameter edit dialog box for the serial communication unit appears, set the communication

parameters separately for the applicable port.

The gateway unit and serial communication unit (CJ1W-SCU41-V1) are connected via the RS485 protocol.

Accordingly, the port to be used is “1” and each item is set as follows:

x

Port 1 optional setting:

Optional setting

x

Port 1 serial communication mode:

Serial gateway

x

Port 1 data length:

8 bits

x

Port 1 stop bit:

1 bit

x

Port 1 parity:

None

x

Port 1 baud rate:

Set the same baud rate specified for the

gateway unit.

(Example) 115200bps

x

Monitoring time for serial gateway response timeout:

0 (default value)

x

Monitoring time for serial gateway send start timeout:

0 (default value)

-363-