Part 1 specification – IAI America REXT User Manual

Page 156

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

132

Part 1 Specification

[4] Monitor current electrical current – Axis (1)

z

Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

03 H

1

Starting address

(upper)

F7 H

Starting address

(lower)

0E H

2

Address of the current electrical current of axis

(1)

Number of registers (upper)

00 H

Number of registers (lower)

02 H

2

Number of registers (1 register = 1 word): 2

Error check

(CRC)

Based on

calculation result

2

(93 62)

Trailer

None

-

Total bytes

8

z

Response

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

03 H

1

Data bytes

04 H

1

1-word register x 2 = 4 bytes

Data 1

(upper)

Arbitrary

Data 1

(lower)

Arbitrary

1 each for upper

and lower words

2

Lower word of the current electrical current

Data 2

(upper)

Arbitrary

Data 2

(lower)

Arbitrary

Same as above Upper word of the current electrical current

Error check

(CRC)

Based on

calculation result

2

Trailer

None

-

Total bytes

z

Actual Example

„

Sent Query:

3F03F70E00029362

„

Received Response: 3F030400260000C43B

(Explanation) x Lower word: 0026 H

x

Upper word: 0000 H

The electrical current data is indicated in unit of 1mA.

In other words, 00000026 H = 38 (decimal) o 38 mA