Part 3 maintenance – IAI America REXT User Manual

Page 395

Advertising
background image



Part 3 Maintenance

Chapter 1 T

roubleshooting

363

Part 3 Maintenance

Code

Alarm name

Cause/action

0CC Control

power-supply

overvoltage

This alarm indicates that the 24-V input power-supply voltage is excessively high (24 V +

20%: 28.8 V or above).

Cause: [1] The 24-V input power-supply voltage is high.

[2] A faulty part inside the controller

Action: Check the input power-supply voltage.

If the voltage is normal, please contact IAI.

0CE Control

power-supply

voltage low

This alarm indicates that the 24-V input power-supply voltage is low (24 V - 20%: 19.2 V

or below).

Cause: [1] The 24-V input power-supply voltage is low.

[2] A faulty part inside the controller

Action: Check the input power-supply voltage.

If the voltage is normal, please contact IAI.

0D2 Motor

power-supply

overvoltage

(RACON only)

Cause: [1] The input power-supply voltage of the motor is high.

[2] A faulty part inside the controller

Action: Check the input power-supply voltage of the motor.

If the voltage is normal, please contact IAI.

0D8 Deviation

overflow

The position deviation counter has overflowed.

Cause: [1] The speed dropped during movement due to the effect of an external force,

etc.

[2] The acceleration is set too high for the loading mass.

Action: [1] Check the load conditions—such as whether the work part is contacting a

surrounding object or the brake is released—and then correct the

abnormality, if any.

[2] An overload condition is suspected, so review the payload.

0D9 Soft limit over

error

Cause: The current position of the actuator is outside the software stroke limits

following the completion of home return.

Action: Move the actuator to a position within the software stroke limits.

0DC Push & hold

operation

out-of-range error

This alarm generates when the actuator was pushed back to the target position due to an

excessive push force after completion of push & hold operation.

Review the entire system.

0ED Absolute encoder

error (1)

Cause: [1]

When the power was reconnected following the completion of an

absolute reset, the current position changed due to an external factor or other cause

occurring while the controller was communicating with the absolute unit.

[2]

When an absolute reset was performed, the current position changed due to an

external factor or other cause occurring while the controller was communicating with the

absolute unit.

Action: [1]

When the detail code is H’0001:

Turn off the power and make sure the actuator is not receiving vibration, etc., and then

turn the power back on.

[2]

When the detail code is H’0002:

Perform the home return operation after making sure the actuator is not receiving

vibration, etc.

-395-

Advertising
This manual is related to the following products: