Part 1 specification – IAI America REXT User Manual

Page 152

Advertising
background image

0

Part 1 Specification

Chapter 3 Gateway R unit

128

Part 1 Specification

(2) Examples of Queries/Responses

Queries are implemented by reading a 1-word register and thus the basic pattern is the same with all queries. The only

differences are the starting address and data.

[1] Read gateway status signal 0, 1

The configuration of the completed position number register of axis (0) is shown below.

z

Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

03 H

1

Starting address

(upper)

F7 H

Starting address

(lower)

00 H

2

Initial address of gateway status signal 0, 1

Number of registers (upper)

00 H

Number of registers (lower)

02 H

2

Number of registers (1 register = 1 word): 2

Error check

(CRC)

Based on

calculation result

2

(F2 A1)

Trailer

None

-

Total bytes

8

Address

Address

Gateway

status signal 0

Gateway

status signal 1

-152-