Part 1 Specification

Chapter 3 Gateway R unit

147

Part 1 Specification

‹

Jogging Speed/Inching Distance Switching Command (JVEL)

In jogging operation and inching operation, the jogging speed and inching distance are determined by referencing the

applicable control parameters. This signal is used to switch these parameters.

JVEL Jogging speed of jogging operation (JISL = “0”)

Inching distance of inching operation (JISL = “1”)

“0”

Parameter No. 26 (Jogging speed)

Parameter No. 48 (Inching distance)

“1”

Parameter No. 47 (Jogging speed 2)

Parameter No. 49 (Inching distance 2)

z

Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

06 H

1

Starting address

(upper)

F6 H

Starting address

(lower)

0B H

2

Address of the control signal register of axis (0)

New data (data written) (upper)

Arbitrary

New data (data written) (lower)

Arbitrary

2

Used in combination with the JISL, JOG+/- and

SON signals.

Error check

(CRC)

16 bits

2

Based on calculation result

Trailer

None

-

Total bytes

8

z

Response

If the data has been changed (written) successfully, the response is the same as the query.

z

Actual Example

„

Sent Query:

3F06F60B -----

„

Received Response: 3F06F60B -----

-171-