4.2 Basic Specifications

The basic specifications are the same between the RACON and RPCON.

Item

Specification

Number of controllable axes

1 axis

Power-supply voltage

24 VDC r 10%

Standard specification, high

acceleration/deceleration type

Energy-saving type

Actuator

Rating

Max. *1

Rating

Max. *1

SA4ySA5yRA4

(20W) type

1.3 A

4.4 A

1.3 A

2.5 A

SA6yRA4 (30W) type

1.3 A

4.0 A

1.3 A

2.2 A

R

C

A

RA3 (20W) type

1.7 A

5.1 A

1.7 A

3.4 A

SA3 (10W) type

SA5yTA6 (20W) type

1.3 A

4.4 A

1.3 A

2.5 A

SA6yTA7 (30W) type

1.3 A

4.0 A

1.3 A

2.2 A

R

C

A2

RA4

y

TA5

(20W) type

1.7 A

5.1 A

1.7 A

3.4 A

RA1LySA1L

0.8 A

4.6 A

RA2LySA2L

1.0 A

6.4 A

RACON

unit

R

C

L

RA3LySA3L

1.3 A

6.4 A

Actuator

Rating

Max. *2

20P, 28P, 28SP motors

0.4 A

2.0 A

Power-supply current

RPCON

unit

42P, 56P motors

1.2 A

2.0 A

Positioning commands

Position number specification, numerical specification

Number of positioning points

768 points

Serial communication

RS485, 1 channel (dedicated connector)

Communication protocol

Modbus protocol

RCP*, RCA*

800 pulses/rev

RA1LySA1L

715 pulses/rev

RA2LySA2L

855 pulses/rev

Encoder

resolution

R

C

L

RA3LySA3L

1145 pulses/rev

Encoder interface

Incremental specification conforming to EIA RS-422A/423A

Backup memory

Position table data and parameters are saved in the nonvolatile memory.

Serial EEPROM rewrite life: 100,000 times max.

LED indicators

Servo ON indicator, alarm indicator, communication status indicator, status indicator

Forced release of electromagnetic

brake

Brake release switch on the front panel

Emergency stop circuit

Built-in drive-source cutoff relay

Ambient operating

temperature

0 to 50qC (*3)

Ambient operating humidity

95% RH max. (non-condensing)

Operating ambience

Free from corrosive gases

Surrounding storage

temperature

-25 to 70qC

Surrounding storage humidity 95% RH max. (non-condensing)

Vibration resistance

XYZ directions:

10 to 57 Hz, half amplitude – 0.035 mm (continuous) / 0.075 mm (intermittent)

57 to 150 Hz – 4.9 m/s

2

(continuous) / 9.8 m/s

2

(intermittent)

E

nv

iro

nm

en

t

Impact resistance

XYZ directions: 147 mm/s

2

, 11 ms, half-sine wave pulse

Protection degree

IP20

Cooling

Forced air cooling (built-in fan)

Weight

200 g

External dimensions

34 W x 105 H x 73.3 D mm

*1 The current becomes the maximum during the excited-phase detection of the servo motor performed when the servo is

turned on for the first time following the power on. (Normal: Approx. 1 to 2 seconds, Maximum: 10 seconds)

*2 The current becomes the maximum during the excited-phase detection performed when the servo is turned on for the first

time following the power on. (Normal: 100 msec)

*3 The ambient operating temperature of a ROBONET system is 0 to 40qC.