Part 1 Specification

Chapter 3 Gateway R unit

165

Part 1 Specification

[1] Write position table data

An example of writing the target position, positioning band and speed data one by one to the position table under No.

10 corresponding to positioner mode axis (0) is explained.

x

Target position

100 m

o

10000 = 2710H

x

Positioning band

0.3 mm

o

30 = 001EH

x

Speed

2 mm/sec

o

200 = 00C8H

z

Target Position Write Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

10 H

1

Starting address

(upper)

F6 H

Starting address

(lower)

02 H

2

Initial request command register address of axis

(0)

Number of registers

(upper)

00 H

Number of registers

(lower)

05 H

2

The number of registers is 5.

Bytes

0A H

1

Number of registers x 2 = 10 (0AH)

New data 1

(upper)

10 H

New data 1

(lower)

00 H

1 each for upper

and lower words

2

Request command (position write)

New data 2

(upper)

00 H

New data 2

(lower)

0A H

1 each for upper

and lower words

2

Data 0: Position No. 10 is specified.

New data 3

(upper)

27 H

New data 3

(lower)

10 H

1 each for upper

and lower words

2

Data 1: Lower word of target position data

New data 4

(upper)

00 H

New data 4

(upper)

00 H

1 each for upper

and lower words

2

Data 2: Upper word of target position data

New data 5

(upper)

00 H

New data 5

(upper)

00 H

1 each for upper

and lower words

2

Data 3: An axis number is specified (axis 0).

Error check

(CRC)

16 bits

2

Based on calculation result (6891)

Trailer

None

-

Total bytes

19

„

Sent Query:

3F10F60200050A1000000A27100000

00006891

„

Received Response: 3F10F6020005969C

Caution

Each gateway command must be cleared after use. If the command area is not cleared, the next command cannot be

accepted.

Query sent in this example: 3F 06 F602 0000 1F5C