Part 2 startup chapter, Caution – IAI America REXT User Manual

Page 292

Advertising
background image

0

Part 2 Startup Chapter

Chapter 2 Mounting and Installation

268

Part 2 Startup Chapter

[6] The RGW-PR connector is a D-Sub, 9-pin Profibus-DP connector (female) recommended in the EN 50170 standard.

Network connectors are not provided.

Pin number Signal name

Explanation

1

NC

Not connected

2

NC

Not connected

3

B-Line

Communication line B (positive side)

4

NC

Not connected

5

GND

Signal ground

6

+5 V

+5-V output

7

NC

Not connected

8

A-Line

Communication line A (negative side)

9

NC

Not connected

Housing

Shield

Cable shield

Caution

The RGW-PR does not have terminal resistor setting switches. If the RGW-PR is connected at the end of a network,

connect a terminal resistor to the network connector or use a connector with terminal resistor, as specified below.

z

Connecting a terminal resistor

z

Profibus connector (with terminal resistor)

(Example) SUBCON-PLUS-PROFIB/AX/SC (Phoenix Contact)

Female connector

on RGW-PR end

Male connector on network

end (view from the side

opposite the insertion side)

Network wiring