Part 3 maintenance – IAI America REXT User Manual

Page 391

Advertising
background image



Part 3 Maintenance

Chapter 1 T

roubleshooting

359

Part 3 Maintenance

Alarm List

*

STATUS

3 2 1 0

Simple

code

Alarm

code

Alarm name

Reset

method

RPCON RACON

90

Software reset command with servo ON

{

{

91

Position number error during teaching

{

{

92

PWRT signal detection during movement

{

{

{

{

z

{

2

93

PWRT signal detection before home return

{

{

80

Movement command with servo OFF

{

{

83

Absolute position movement command before home

return

{

{

84

Movement command during home return

{

{

85

Position number error during movement

{

{

{

{

z

z

3

A7

Command deceleration error

{

{

{

z

{

{

4

F4

Unmatched PCB error

z

{

{

A1

Parameter data error

{

{

A2

Position data error

{

{

{

z

z

{

6

A3

Position-command information data error

{

{

B6

Phase-Z detection timeout

x

{

B7

Indeterminable magnetic pole

z

x

{

B8

Excitation detection error

z

{

x

BA

Home sensor not detected

{

{

{

z

z

z

7

BE

Home return timeout

{

{

z

{

{

{

8

C0

Excessive actual speed

{

{

C8

Overcurrent

z

x

{

C9

Overvoltage

{

{

CA Overheat

{

{

CB Current-sensor offset adjustment error

z

x

{

CC Control power-supply voltage error

{

{

z

{

{

z

9

CE Control power-supply voltage low

{

{

D8

Deviation overflow

{

{

D9

Software stroke limit over error

{

{

z

{

z

z

B

DC Push & hold operation out-of-range error

{

{

C1

Servo error

{

{

D2

Excessive motor power-supply voltage

{

x

E0

Overload

z

x

{

z

z

{

{

C

F0

Driver logic error

z

x

{

E5

Encoder receive error

z

x

{

E8

Phase A/B open

z

{

{

E9

Phase A open

z

{

{

EA

Phase B open

z

{

x

ED Absolute encoder error (1)

z

{

x

EE

Absolute encoder error (2)

{

{

z

z

{

z

D

EF

Absolute encoder error (3)

{

{

z

z

z

{

E

FA

CPU error

z

{

{

F5

Nonvolatile memory write verification error

{

{

F6

Nonvolatile memory write timeout

{

{

z

z

z

z

F

F8

Damaged nonvolatile memory data

z

{

{

{

: Unlit z: Lit

{

: Available X: Not available

* Alarms denoted by z in the “Reset method” field are cold-start alarms. These alarms cannot be reset unless the power is

turned off once. Other alarms can be reset by inputting the reset signal.