Part 1 specification, Caution – IAI America REXT User Manual

Page 193

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

169

Part 1 Specification

<Reading of Response Command Area>

Send a register read (FC = 03H) query.

„

Sent Query:

3F03F702000512A3

„

Received Response: 3F030A 1040 000A 27100000 0000 2E8A

Position data

The position data (2710H) written to the position table in [1] has been

read.

Caution

Each gateway command must be cleared after use.

z

Positioning Band Read Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

10 H

1

Starting address

(upper)

F6 H

Starting address

(lower)

02 H

2

Initial request command register address of axis

(0)

Number of registers

(upper)

00 H

Number of registers

(lower)

05 H

2

The number of registers is 5.

Bytes

0A H

1

Number of registers x 2 = 10 (0AH)

New data 1

(upper)

10 H

New data 1

(lower)

41 H

1 each for upper

and lower words

2

Request command (read positioning band)

New data 2

(upper)

00 H

New data 2

(lower)

0A H

1 each for upper

and lower words

2

Data 0: Position No. 10 is specified.

New data 3

(upper)

00 H

New data 3

(lower)

00 H

1 each for upper

and lower words

2

Data 1: 0

New data 4

(upper)

00 H

New data 4

(upper)

00 H

1 each for upper

and lower words

2

Data 2: 0

New data 5

(upper)

00 H

New data 5

(upper)

00 H

1 each for upper

and lower words

2

Data 3: An axis number is specified (axis 0).

Error check

(CRC)

16 bits

2

Based on calculation result (93D6)

Trailer

None

-

Total bytes

19

„

Sent Query:

3F10F60200050A 1041 000A 00000000

0000 9D36

„

Received Response: 3F10F6020005969C

-193-