Network type

CC-Link

DeviceNet

PROFIBUS

EtherNet/IP

RS485SIO

Modbus

gateway mode

SIO through

mode

[7] Address

A value from 1 to
64 can be set.
(Normally 1
represents the
master unit.)

A value from 0 to
63 can be set.
(Normally 63
represents the
master unit.)

A value from
1 to 125 can
be set.

0.0.0.0 to
255.255.255.255

Fixed to 63.

-

[8] Baud rate

156 kbps
625 kbps
2.5 Mbps
5 Mbps
10 Mbps

Set
automatically.

Set
automatically.

Set
automatically.
10 Mbps,
half-duplex
10 Mbps,
full-duplex
100 Mbps,
half-duplex
100 Mbps,
full-duplex

9.6 kbps
19.2 kbps
38.4 kbps
57.6 kbps
115.2 kbps
230.4 kbps

38.4 kbps
57.6 kbps
115.2 kbps
230.4 kbps

[10] Displayed
occupancy
information and
I/O sizes
(bytes)

-

Number of (positioner 1/simple direct mode) axes x 8 + Number of
direct numerical specification (positioning) mode axes x 16 + 16
Or,
Number of (positioner 2/solenoid valve mode 1/solenoid valve mode
2) axes x 4

-



P

ar
t 1

S

p

ec
if

ica
tion

Ch
apt

er

3
G

atew

a

y
R
u

n

it

-309-