Part 2 Startup Chapter

Chapter 2 Mounting and Installation

265

Part 2 Startup Chapter

(2) DeviceNet

Check the operation manual for the master (PLC) for details on DeviceNet. The following explains the points to note

regarding network wiring.

An example of network connection is shown below.

(1) An equipment connected to a network and having an assigned address is called a “node.” A node may be the master

(DeviceNet unit in the above figure) that manages the DeviceNet network, or a slave that connects external I/Os to the

network. Both master and slave nodes can be set in any positions.

(2) A terminal resistor is required on both ends of a trunk line (bold line in the figure). A cable branching from a trunk line

(normal line in the figure) is called a “branch line.”

Use a dedicated 5-wire cable for DeviceNet. Select a thick cable or thin cable according to the supplied current.

The dedicated cable is explained on the ODVA website.

The details of the dedicated cable are as follows.

Color

Signal type

Red

Power cable + (V+)

White Communication data high (CAN H)

---

Shield

Blue Communication data low (CAN L)

Black

Power cable - (V-)

DeviceNet unit (master)

Node

T-branch tap

Trunk line

Node

Node

Node Node

Node Node

Node

Node

Communication

power supply

24 VDC

With terminal

resistor

Branch

line

With terminal

resistor

Colors of wires are

also printed on the

dedicated connector.