Part 3 Maintenance

Chapter 1 T

roubleshooting

364

Part 3 Maintenance

Code

Alarm name

Cause/action

0EE Absolute encoder

error (2)

Cause: [1] The power was turned on for the first time after the battery connection.

[2] When the detail code is H’0001:

The battery voltage dropped to a level where the encoder counter in the

absolute unit could no longer be retained.

[3] When the detail code is H’0002:

The encoder connector was unplugged during a power outage, or the

encoder cable was disconnected.

[4] When the detail code is H’0003:

A relevant parameter was changed.

[5] When the detail code is H’0004:

The battery voltage dropped to 3.1 V.

[6] When the detail code is H’0005:

No battery is connected.

Action: If [1], [2] or [4] is suspected, perform an absolute reset by following the specified

procedure. (Refer to the absolute reset method in 4.5.)

[3] or [5]: Supply power for at least 48 hours to fully charge the battery, and then

perform an absolute reset.

* It takes 72 hours to fully charge the discharged battery.

[6] Check the battery connection.

0EF Absolute encoder

error (3)

Cause: The current value changed at a speed equal to or greater than the specified

speed due to an external factor or other cause occurring when the power was

cut off.

Action: Change the applicable settings in the simple absolute unit and take other

measures to prevent the actuator from moving at or above the specified speed

while the power is cut off.

If the battery retention time has an ample allowance, increase the specified

motor speed.

(Refer to 4.2 in “Startup”)

If this error has occurred, perform an absolute reset according to the specified

procedure.