Part 2 Startup Chapter

Chapter 5 Network Setup

323

Part 2 Startup Chapter

(3) Inserting the gateway rack into the network

Insert the rack module by dragging “ANYBUS-S PDP” in the catalog window and dropping it over the master system, as

shown below.

The address is set automatically. To change the address, do so in the Properties dialog box. The address of the gateway

rack must correspond to the address switch setting of the gateway.

<Inserting the rack into the network>

(4) Setting I/O assignments – Inserting the universal module

Insert the universal module into the rack described in the preceding step, as shown below. Since the universal module

provides only up to 64 input bytes and 64 output bytes, another universal module must be inserted if 10 or more axes are

used.

<Inserting the universal module into the rack>