Part 1 specification, Caution – IAI America REXT User Manual

Page 204

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

180

Part 1 Specification

4. Error pattern, with request

Caution

Notes on using the FB

x

Do not issue position data write commands successively, because these commands are

written to the flash memory area. The flash memory can be written only so many times.

x

If communication is cut off while the axis is moving (during jogging operation, etc.), the axis

will continue to operate. To prevent danger, provide a measure to allow the axis to be stopped

externally.

x

Do not use multiple instances of the same name. Duplication of assigned addresses will inhibit

normal operation.

EN input condition

Connect the FB start condition input to the “start trigger” signal.

This FB is of constant execution type.

Limitation

- Input variables

x

If the value of any input variable is out of range, the ENO will be turned OFF and the FB will

not be executed.

- Output variables

x

Do not turn ON/OFF the output variable FB_BUSY from outside the FB.

GW control command

Command

Data write command

FB_Busy

GW control write

Command write

Axis data write

GW information read

Successful response

Error response

Error clear

If an error is received, the current communication will

be interrupted. However, commands will be received

continuously from the next processing.

-204-