Part 1 specification – IAI America REXT User Manual

Page 133

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

109

Part 1 Specification

(2) Pause

When the pause command signal (STP) is turned “1” (ON) while the actuator is moving, the actuator will decelerate to a

stop.

Since the remaining travel distance is retained, the remaining travel can be resumed by turning the SPT “0” (OFF) again.

The remaining travel can be cancelled by turning the reset signal (RES) “1” (ON) while the actuator is paused. When the

cancellation of the pause command (STP) is recognized thereafter, the position complete signal (PEND) will turn “1”

(ON) within approx. 1 msec.

(The command is cancelled upon detection of the leading edge of the reset signal.)

Command position

Position start

(CSTR)

Position complete

(PEND)

Moving (MOVE)

Actuator movement

Completed position

Pause command

(STP)

4 msec Max

Decelerate to a stop

Start of remaining travel

Speed

Command position

Position start

(CSTR)

Position complete

(PEND)

Moving (MOVE)

Actuator movement

Completed position

Pause command

(STP)

Speed

Reset (RES)

Approx. 1 msec