Part 2 Startup Chapter

Chapter 2 Mounting and Installation

256

Part 2 Startup Chapter

2.2.5 Multi-stage ROBONET Layout

An example of a multi-stage layout

achieved by using REXT extension units

is shown to the right.

(1) The units are installed on DIN rails.

(2) Each extension unit connected to

the downstream side (stage below)

is placed at the far right in each

stage. (Extension units [1] and [3])

(3) Each extension unit connected to

the upstream side (stage above) is

placed at the far left in each stage.

(Extension units [2] and [4])

(4) The extension units on the

upstream side (in the stage above)

and downstream side (in the stage

below) are connected using a unit

link cable (CB-REXT-SIO-), and the

grounding wire with a M3 round

terminal is connected to the FG

terminal block on each upstream

extension unit. (Extension units [1]

and [3])

Connect the FG terminals on the

downstream extension units ([2],

[4]) to the grounding terminal on the

control panel in the same manner

as with the Gateway R unit.

(5) Connect each extension unit to an

adjacent unit using the power

supply connection plate and

communication connection circuit

board supplied with the extension

unit.

(6) Install the terminal resistor circuit

board (supplied with the Gateway R

unit) on the last controller unit.

Unit link cable

GatewayR unit

Extension unit [1]

Extension unit [2]

Extension unit [4]

Unit link cable

Extension unit [3]

-280-