.. Backup Battery

The absolute specification uses a secondary battery (nickel hydrogen battery) to retain absolute counter data in the FPGA and

supply power to the encoder drive circuit even when the power is cut off.

() Battery Specifications

n

o

it

p

ir

c

s

e

D

m

e

tI

Classification

Cylindrical sealed nickel hydrogen battery

Manufacturer

Sanyo Electric Co., Ltd.

Model

AB-

Nominal voltage

. V (. V x )

Rated capacity

00 mAh

Average life

 years

Weight

0 g

Charge time

Approx.  hours (continuous)

() Charging the Battery

Always charge the battery when starting the delivered unit and after replacing the battery.

The battery is charged automatically when the controller power is supplied, so keep the main power supply on for at least

 hours.

The actuator can be moved and the position table changed while the battery is charging. Also charge the battery

continuously for at least  hours after the power has been cut off for a prolonged period (but within the specified battery

retention time).

For the specified battery retention time, refer to “Setting switches” in ...

() Replacing the Battery

The battery is a consumable part. Repeated charges will cause the battery characteristics to deteriorate. If you notice that

the battery becomes low very quickly, the battery has probably reached its life. In this case, replace the battery.

Although the replacement interval varies depending on the ambient temperature and discharge condition, as a guide the

battery should be replaced after approx.  years of connecting to the controller.

The battery unit has a label that specifies the date three years from the shipment date.

[Refer to Part  Maintenance, section .]

Use this date as a guide.

Caution

() Applying vibration, impact, etc., to the actuator or moving the slider, etc., while the power is cut off may cause loss of

absolute data.

If the RDY/ALM LED and STATUS  LED on the front panel of the simple absolute R unit illuminate in green and red,

respectively, the next time the power is turned on, an absolute encoder error has occurred. In this case, an alarm reset

and home return must be performed.

Do not move the slider or rod while the power is cut off.

() Since the charge efficiency is particularly affected by the ambient temperature during charge, it is recommended that

the unit be used at normal temperature (+0 to +0 C).

If the ambient temperature exceeds  C, the charge efficiency will drop and the battery will not be charged fully. What

is worse, lower battery performance or leakage of battery fluid may also occur.