Part 3 maintenance, 2 alarms, causes and actions – IAI America REXT User Manual

Page 392

Advertising
background image



Part 3 Maintenance

Chapter 1 T

roubleshooting

360

Part 3 Maintenance

1.3.2 Alarms, Causes and Actions

(1) Operation-cancellation alarms (These alarms can be reset with the reset signal.)

Code

Alarm name

Cause/action

080

Movement

command with

servo OFF

Cause: A movement command was issued as a numerical command when the servo

was OFF.

Action: Confirm that the servo is ON (SV or PEND is “1”) before issuing a movement

command.

083

Numerical

command before

home return

Cause: A numerical command involving an absolute position was issued before home

return was completed. (Simple direct or direct numerical command mode)

Action: Perform home return and confirm a completion signal (HEND) before issuing a

movement command.

084

Movement

command during

home return

Cause: A movement command was issued as a numerical command while home return

was in progress.

Action: Perform home return and confirm a completion signal (HEND) before issuing a

movement command.

085

Position number

error during

movement

Cause: A position number not yet registered in the position table was specified in the

positioner mode.

Action: Check the position table again.

090

Software reset

with servo ON

Cause: A software reset command was received when the servo was ON.

Action: Send a software reset command to the controller after confirming that the servo

is OFF (SV is “0”).

091

Position number

error during

teaching

Cause: An invalid position number was specified when writing the current position via

teaching operation.

Action: 768 position numbers from 0 to 767 can be used with the RACON and RPCON.

Use position numbers within this range.

092

PWRT signal

detection during

movement

Cause: The current position write signal (PWRT) was input during jogging when

teaching operation was performed in the positioner mode.

Action: Input the PWRT signal after confirming that no jog button is pressed and that

the axis is stopped (MOVE signal is “0”).

093

PWRT signal

detection before

home return

Cause: The current position write signal (PWRT) was input before home return was

completed when teaching operation was performed in the positioner mode.

Action: Input the HOME signal first to perform home return and confirm the completion

of home return (HEND signal is “1”) before inputting the PWRT signal.

-392-