Part 1 Specification

Chapter 3 Gateway R unit

59

Part 1 Specification

(4) Error Responses

If a command error occurs, the most significant bit (b15) of the response command will turn ON and an error code will be

set in response data 1.

Code

Explanation

0101H

Invalid axis number *1

0102H

Invalid position number *1

0103H

Invalid request command *1

0201H

Communication failed

0202H

Controller could not execute the command

*1 If an error is found in the data from the PLC as a result of check, the data will not be sent to the controller, but an

error code will be set in the response data instead.

*2 If no link is established yet, nothing will be shown in the response command.

(5) How to Use Commands

To use various commands, process the data in command areas according to the flow shown below. In this flow, only one

command is processed.

Use a command

Clear the request command

area and data areas 0 to 3.

Response

command area 0?

Write the command code in

the request command area

Write the necessary data in

data areas 0 to 3

Response command =

Request command?

Clear the request command area

Clear data areas 0 to 3