Part 3 Maintenance

Chapter 2 Maintenance/Inspection

373

Part 3 Maintenance

2.3 Replacing the Backup Battery

The backup battery for simple absolute R unit lasts for three years. The expiration date label is attached on the front face of

the battery, as shown below. Replace the backup battery if the expiration date has passed, even when the battery is not faulty.

<Replacement procedure for backup battery>

(1) To ensure safety, stop all axis operations and turn off the power.

(2) Unplug the backup battery connector and pull out the battery from the unit.

(3) Set a new battery in the unit and plug in the battery connector.

(4) Turn on the power.

(5) Perform an absolute reset of each applicable axis.

The absolute reset procedure is the same as the method used at startup. Refer to 4.5 Startup in Part 2.

Backup battery

Expiration date label

AB-7
To be replaced by: February 2010

(Example of

description)

Front view of simple absolute R unit

(cover open)

[Items to Prepare]

Backup battery for replacement

AB- (IAI model code)

[Replacement Process]

() To ensure safety, stop all axis operations and turn off the power.

() Open up the covers on the units (RACON and RPCON) that Simple Absolute R Unit and Absolute Unit are

connected to and pull the connector of the backup battery to front to disconnect the connector.

Backup Battery

Connector

-405-