Part 1 Specification

Chapter 3 Gateway R unit

133

Part 1 Specification

[5] Monitor current speed – Axis (1)

z

Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

03 H

1

Starting address

(upper)

F7 H

Starting address

(lower)

10 H

2

Address of the current speed data of axis (1)

Number of registers (upper)

00 H

Number of registers (lower)

01 H

2

Number of registers (1 register = 1 word): 1

Error check

(CRC)

Based on

calculation result

2

(B3 65)

Trailer

None

-

Total bytes

8

z

Response

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

03 H

1

Data bytes

02 H

1

1-word register x 1 = 2 bytes

Data 1

(upper)

Arbitrary

Data 1

(lower)

Arbitrary

1 each for upper

and lower words

2

Current speed data

Error check

(CRC)

Based on

calculation result

2

Trailer

None

-

Total bytes

z

Actual Example

„

Sent Query:

3F03F7100001B365

„

Received Response: 3F030200009181

(Explanation) The current speed data is “0000H.”

In other words, the current speed is “0” in this example.

The current speed is indicated in units of 1.0 mm/sec.

The current speed is set as a multiple of 1.0 mm/sec or 0.1 mm/sec.

The unit is changed on the special parameter setting screen of the ROBONET gateway parameter

creation tool. (The unit change function is supported by tools of version 1.0.4.0 and later.)