Part 1 specification – IAI America REXT User Manual

Page 128

Advertising
background image

0

Part 1 Specification

Chapter 3 Gateway R unit

104

Part 1 Specification

[1]

[2]

[3]

[4]

[3]

[3]

Rear end movement command input (ST0)

Intermediate point movement command input (ST2)

Positioning band for

position No. 0

Rear end

Intermediate point

Front end

Positioning band for

position No. 2

Positioning

band for

position No. 1

(7) Operation in solenoid valve mode 2

Enter position data beforehand in the position table of the controller, and specify each desired position number using the

corresponding link register on the PLC.
ڦ

Operation

[1] Set all movement command bits to “0” (turn all movement command signals OFF).

[2] Set the movement command bit (front end movement command in the example below) to “1” (turn the signal

ON).

[3] When the current position of the actuator enters the range of the value set in the position table r positioning

band (INP), each position detection is output.

[4] Set the movement command bit to “0” (turn the signal OFF) after confirming that the position detection output bit

for the target position (front end position detection output in the example below) has changed to “1” (the signal

has turned ON).

Front end movement command input

Front end movement command input

Intermediate position detection output

Front end position detection output

Actuator movement

-128-