Part 1 Specification

Chapter 3 Gateway R unit

42

Part 1 Specification

„

Example of Overall CC-Link Address Configuration

(Positioner 1 mode/simple direct mode + Direct numerical specification mode)

An example of connecting 12 axes operating in the positioner 1 mode or simple direct mode and two axes operating in the

direct numerical specification mode is shown.

PLC output Ÿ ROBONET

ROBONETŸ PLC input

Output

register

Upper byte

Lower byte

Input

register

Upper byte

Lower byte

RY0F to 00

Gateway control signal 0

RX0F to 00

Gateway status signal 0

RY1F to 10

Gateway control signal 1

RX1F to 10

Gateway status signal 1

RY2F to 20

Request command

RX2F to 20

Response command

RY3F to 30

Data 0

RX3F to 30

Data 0

RY4F to 40

Data 1

RX4F to 40

Data 1

RY5F to 50

Data 2

RX5F to 50

Data 2

RY6F to 60

Data 3

RX6F to 60

Data 3

RY7F to 70

(Cannot be used)

RX7F to 70

(Cannot be used)

8-word

fixed area

*1

Output register

Input register

PLC master expanded

cyclic setting

R

Ww 00H (Axis 0) Position data specification (L)

R

Wr 00H

(Axis 0) Current position data (L)

R

Ww 01H (Axis 0) Position data specification (H)

R

Wr 01H

(Axis 0) Current position data (H)

R

Ww 02H

(Axis 0) Command position number

R

Wr 02H

(Axis 0) Completed position number

R

Ww 03H

(Axis 0) Control signal

R

Wr 03H

(Axis 0) Status signal

4 words

Positioner/

simple direct

mode

R

Ww 04H (Axis 1) Position data specification (L)

R

Wr 04H

(Axis 1) Current position data (L)

R

Ww 05H (Axis 1) Position data specification (H)

R

Wr 05H

(Axis 1) Current position data (H)

R

Ww 06H

(Axis 1) Command position number

R

Wr 06H

(Axis 1) Completed position number

R

Ww 07H

(Axis 1) Control signal

R

Wr 07H

(Axis 1) Status signal

4 words

R

Ww 08H (Axis 2) Position data specification (L)

R

Wr 08H

(Axis 2) Current position data (L)

R

Ww 09H (Axis 2) Position data specification (H)

R

Wr 09H

(Axis 2) Current position data (H)

R

Ww 0AH

(Axis 2) Command position number

R

Wr 0AH

(Axis 2) Completed position number

R

Ww 0BH

(Axis 2) Control signal

R

Wr 0BH

(Axis 2) Status signal

4 words

R

Ww 0CH (Axis 3) Position data specification (L)

R

Wr 0CH

(Axis 3) Current position data (L)

R

Ww 0DH (Axis 3) Position data specification (H)

R

Wr 0DH

(Axis 3) Current position data (H)

R

Ww 0EH

(Axis 3) Command position number

R

Wr 0EH

(Axis 3) Completed position number

16 words

x1 setting,

4 stations

*2

R

Ww 0FH

(Axis 3) Control signal

R

Wr 0FH

(Axis 3) Status signal

4 words

























32 words

x4 setting,

2 stations

R

Ww 1FH

(Axis 7) Control signal

R

Wr 1FH

(Axis 7) Status signal

























R

Ww 2FH

(Axis 11) Control signal

R

Wr 2FH

(Axis 11) Status signal

4 words

RWw 30H (Axis 12) Position data specification (L)

R

Wr 30H

(Axis 12) Current position data (L)

RWw 31H (Axis 12) Position data specification (H)

R

Wr 31H

(Axis 12) Current position data (H)

RWw 32H

(Axis 12) Positioning band specification (L)

R

Wr 32H

(Axis 12) Current electrical current (L)

RWw 33H

(Axis 12) Positioning band specification (H)

R

Wr 33H

(Axis 12) Current electrical current (H)

RWw 34H

(Axis 12) Speed specification

R

Wr 34H

(Axis 12) Current speed data

RWw 35H

(Axis 12) Acceleration/deceleration specification

R

Wr 35H

(Cannot be used)

RWw 36H

(Axis 12) Push-current limiting value

R

Wr 36H

(Axis 12) Alarm code

RWw 37H

(Axis12) Control signal

R

Wr 37H

(Axis 12) Status signal

8 words

Direct

numerical

specification

mode

RWw 38H (Axis 13) Position data specification (L)

R

Wr 38H

(Axis 13) Current position data (L)

RWw 39H (Axis 13) Position data specification (H)

R

Wr 39H

(Axis 13) Current position data (H)

RWw 3AH

(Axis 13) Positioning band specification (L)

R

Wr 3AH

(Axis 13) Current electrical current (L)

RWw 3BH

(Axis 13) Positioning band specification (H)

R

Wr 3BH

(Axis 13) Current electrical current (H)

RWw 3CH

(Axis 13) Speed specification

R

Wr 3CH

(Axis 13) Current speed data

RWw 3DH

(Axis 13) Acceleration/deceleration specification

R

Wr 3DH

(Cannot be used)

RWw 3EH

(Axis 13) Push-current limiting value

R

Wr 3EH

(Axis 13) Alarm code

64 words

x8 setting,

2 stations

RWw 3FH

(Axis13) Control signal

R

Wr 3FH

(Axis 13) Status signal

8 words

*1 The extended cyclic setting is based on the occupied area information displayed using the gateway parameter setting tool.

*2 CC-Link Version 1.10 is also supplied as long as the expanded cyclic setting of x1 (four stations occupied) can be used.

-62-