Part 1 Specification

Chapter 2 System Configuration and General Specifications

19

Part 1 Specification

2.5 Connection Diagram

Shown below is a connection diagram of a ROBONET system comprising of a RPCON and a RACON connected to a simple

absolute R unit.

24-V power supply

Terminal block

Emergency stop circuit

RPCON

encoder cable port

RACON

encoder cable

(CB-ACS-PA***)

Gateway R unit

Field network

connector

PG (white)

Simple

absolute R unit

PG (red)

Motor cable (CB-RCP2-MA***)

RPCON encoder cable (CB-RCP2-PA***)

Motor cable (CB-ACS-MA***)

RACON encoder cable port

(Simple absolute R unit not connected)