Chapter 2 Mounting and Installation

260

Part 2 Startup Chapter

yellow

orange

blue

The following parts are supplied.

[1] 4-way junction

[2] e-CON connector

[3] Terminal resistor

Model: 5-1473574-4

4-1473562-4

Outer sheath size of applicable wire

220 :

1/4 W

Manufacturer: AMP

Quantity: 1

Manufacturer: AMP

Quantity: 1

1.35 to 1.6 mm

With e-CON connector

Quantity: 1

Controller end

Signal

e-CON connector

3-1473562-4

(Housing color: Orange)

<Fabrication of Junction Interconnection Cable>

[1] Strip the sheath of the 2-pair shielded cable by 15 to 20

mm.

[2] Strand the shielded wires and solder them to vinyl wires

of AWG22 or equivalent.

[3] Slide a cable protection tube onto the cable.

[4] Insert the four core wires into the cable insertion holes in

the connector without stripping the wires. (SDA, SDB,

GND, FG)

[5] With the cable inserted, pressure-weld the press-fit

cable housing from above.

[6] Heat and shrink the cable protection tube.

e-CON connector pin numbers

Be sure to insert a terminal resistor (220 :, 1/4 W) at each end of the main

communication line (between Nos. 1 and 2 on the e-CON connector).

<Controller Link Cable> (CB-RCB-CTL002)

This cable is an option for each controller and must be purchased separately.

e-CON connector

Pressure-welded

Vinyl wire

(AWG22)

Soldered

Shielded wire

Locking tab

Cable tube

2-pair shielded cable

Locking tab

e-CON connector

2-pair shielded cable

Recommended: Taiyo Electric Wire & Cable e-CON connector

(4-1473562-4 by AMP: Green)

Mini-DIN connector

Signal

-284-