Part 1 Specification

Chapter 3 Gateway R unit

46

Part 1 Specification

(3) Profibus

„

Example of Overall Profibus Address Configuration

(Positioner 1 mode/simple direct mode + Direct numerical specification mode)

An example of connecting 12 axes operating in the positioner 1 mode or simple direct mode and two axes operating in the

direct numerical specification mode is shown.

PLC output Ÿ ROBONET

ROBONETŸ PLC input

Relative

byte*

Upper byte

Lower byte

Upper byte

Lower byte

0

Gateway control signal 0

Gateway status signal 0

2

Gateway control signal 1

Gateway status signal 1

4

Request command

Response command

6

Data 0

Data 0

8

Data 1

Data 1

10

Data 2

Data 2

12

Data 3

Data 3

14

(Cannot be used)

(Cannot be used)

8-word

fixed area

16

(Axis 0) Position data specification (L)

(Axis 0) Current position data (L)

18

(Axis 0) Position data specification (H)

(Axis 0) Current position data (H)

20

(Axis 0) Command position number

(Axis 0) Completed position number

22

(Axis 0) Control signal

(Axis 0) Status signal

4 words

Positioner/

simple direct

mode

24

(Axis 1) Position data specification (L)

(Axis 1) Current position data (L)

26

(Axis 1) Position data specification (H)

(Axis 1) Current position data (H)

28

(Axis 1) Command position number

(Axis 1) Completed position number

30

(Axis 1) Control signal

(Axis 1) Status signal

4 words

31

(Axis 2) Position data specification (L)

(Axis 2) Current position data (L)

34

(Axis 2) Position data specification (H)

(Axis 2) Current position data (H)

36

(Axis 2) Command position number

(Axis 2) Completed position number

38

(Axis 2) Control signal

(Axis 2) Status signal

4 words

40

(Axis 3) Position data specification (L)

(Axis 3) Current position data (L)

42

(Axis 3) Position data specification (H)

(Axis 3) Current position data (H)

44

(Axis 3) Command position number

(Axis 3) Completed position number

46

(Axis 3) Control signal

(Axis 3) Status signal

4 words



















78

(Axis 7) Control signal

(Axis 7) Status signal



















110

(Axis 11) Control signal

(Axis 11) Status signal

4 words

112

(Axis 12) Position data specification (L)

(Axis 12) Current position data (L)

114

(Axis 12) Position data specification (H)

(Axis 12) Current position data (H)

116

(Axis 12) Positioning band specification (L)

(Axis 12) Current electrical current (L)

118

(Axis 12) Positioning band specification (H)

(Axis 12) Current electrical current (H)

120

(Axis 12) Speed specification

(Axis 12) Current speed data

122

(Axis 12) Acceleration/deceleration specification

(Cannot be used)

124

(Axis 12) Push-current limiting value

(Axis 12) Alarm code

126

(Axis12) Control signal

(Axis 12) Status signal

8 words

Direct

numerical

specification

mode

128

(Axis 13) Position data specification (L)

(Axis 13) Current position data (L)

130

(Axis 13) Position data specification (H)

(Axis 13) Current position data (H)

132

(Axis 13) Positioning band specification (L)

(Axis 13) Current electrical current (L)

134

(Axis 13) Positioning band specification (H)

(Axis 13) Current electrical current (H)

136

(Axis 13) Speed specification

(Axis 13) Current speed data

138

(Axis 13) Acceleration/deceleration specification

(Cannot be used)

140

(Axis 13) Push-current limiting value

(Axis 13) Alarm code

142

(Axis13) Control signal

(Axis 13) Status signal

8 words

* The relative byte indicates the relative byte address from the beginning of the gateway.

-66-