Part 1 specification, 3 specifications, 1 general specifications – IAI America REXT User Manual

Page 248

Advertising
background image



Part 1 Specification

Chapter 5 Simple

Absolute R Unit

224

Part 1 Specification

5.3 Specifications

5.3.1 General Specifications

Model

RABU

Power-supply voltage

24 VDC r 10%

Power-supply current

MAX 300 mA

Environment

Ambient operating temperature 0 to 40qC
Ambient operating humidity

95% RH max. (non-condensing)

Operating ambience

Free from corrosive gases and dust.

Surrounding storage

temperature

0 to 40qC (If a battery is included, approx. 20qC is desired.)

Surrounding storage humidity

95% RH max. (non-condensing)

Vibration resistance

XYZ directions:

10 to 57 Hz, half amplitude – 0.035 mm (continuous)

0.075 mm (intermittent)

57 to 150 Hz – 4.9 m/s

2

(continuous) / 9.8 m/s

2

(intermittent)

Impact resistance

XYZ directions: 147 mm/s

2

, 11 ms, half-sine wave pulse

Protection degree

IP20

Weight

330 g (including the backup battery)

Outer diameter

34 W x 105 H x 73.3 D [mm]