Part 1 specification – IAI America REXT User Manual

Page 139

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

115

Part 1 Specification

[2] Notes on positioning operation

If a position number specified in relative coordinates is selected/entered and a start signal is input during positioning

operation, the actuator will move to the initial target position plus the relative travel distance. (If the relative travel

distance is a negative value, the actuator will move to the initial target position less than the relative travel distance.)

Example) If a start signal is input for positioning to position 2 while the actuator is moving to position 1, the actuator

will travel to a position 40 mm from home.

If during positioning operation a start signal is input multiple times for a position number specified in relative

coordinates, the actuator will move to the initial target position plus “relative travel distance x number of times the

signal is input.”

Example) If a start signal is input twice while the actuator is moving to position 1, the actuator will travel to a position

50 mm from home.

Command position

Start

Position complete

Moving

Actuator movement

Completed position

Speed

Position 1 Position 2

Position 2

Position from home: 40

Distance

<Position Table of Teaching Pendant>

Position

Speed

Command position

Start

Position complete

Moving

Actuator movement

Completed position

Speed

Position 1 Position 2

Position 2

Position from home: 50

Distance

-139-

Advertising
This manual is related to the following products: