Part 1 Specification

Chapter 3 Gateway R unit

74

Part 1 Specification

I/O Signal List

Signal type

Bit

Signal name

Description

Details

Push-current

limiting value

8-bit

data

-

Set the push-current limiting value as a hexadecimal number

(unit: %) to set the push force.

The setting range is 00H to FFH, where FFH and 1FFH

correspond to 100% and 200%, respectively.

Example) To set 50%, specify FFH x 50% = 255 x 50% = 127

(decimal number) = “7FH.”

3.8.3 (5)

b15

BKRL

Forced brake release

3.8.2 (19)

b14

-

Cannot be used.

-

b13

DIR

Push direction specification

(0 = Home return direction, 1 = Opposite home return direction)

b12

PUSH

Push operation mode specification

3.8.3 (5)

3.8.4 (1)

b11

-

Cannot be used.

-

b10

-

Cannot be used.

-

b9

-

Cannot be used.

-

b8

JOG+

Jog+ command

b7

JOG-

Jog- command

3.8.2 (14)

b6

JVEL

Jogging speed/inching distance switching

3.8.2 (15)

b5

JISL

Jogging/inching switching

3.8.2 (16)

b4

SON

Servo ON command

3.8.2 (5)

b3

RES

Reset command

3.8.2 (4)

b2

STP

Pause command

3.8.2 (10)

3.8.4 (2)

b1

HOME

Home return command

3.8.2 (6)

P

LC

o

ut

pu

t

Control signal

b0

CSTR

Start command

3.8.2 (7)

-96-