Part 1 specification – IAI America REXT User Manual

Page 90

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

68

Part 1 Specification

I/O Signal List

Signal type

Bit

Signal name

Description

Positioner Simple

direct

Details

Position data

specification

32-bit

data

-

Set as a hexadecimal number using a 32-bit

signed integer (unit: 0.01 mm)

Example) To set +25.4 mm, specify

“0009EC” (decimal number: 2540).

z

The maximum settable value is +9999.99

mm = 999999 (decimal number) =

0F423FH (hexadecimal number).

z

If the applicable data is a negative value,

specify it as a complement of 2.

X

{

3.8.3

(4)

Set the command position number as a binary

number.

{

X

3.8.2 (11)

Command

position number b9-b0

PC***

Move data other than the specified position

data is set in the position table. Specify the

position number as a binary number.

X

{

3.8.3 (3)

b15

BKRL

Forced brake release

{

{

3.8.2 (19)

b10

MODE

Teaching mode command

{

X

3.8.2 (17)

b9

PWRT

Position data load command

{

X

3.8.2 (18)

b8

JOG+

Jog+ command

{

{

3.8.2 (14)

b7

JOG-

Jog- command

{

{

b6

JVEL

Jogging speed/inching distance switching

{

{

3.8.2 (15)

b5

JISL

Jogging/inching switching

{

{

3.8.2 (16)

b4

SON

Servo ON command

{

{

3.8.2 (5)

b3

RES

Reset command

{

{

3.8.2 (4)

b2

STP

Pause command

{

{

3.8.2 (10)

3.8.4 (2)

b1

HOME

Home return command

{

{

3.8.2 (6)

P

LC

o

ut

pu

t

Control signal

b0

CSTR

Start command

{

{

3.8.2 (7)

{

: Available X: Not available